MULTIPARA MONITOR

FEATURES

  •  Advanced streamline outline design, compact, lightweight, in-built handle makes it truly portable.
  •  Can be used to monitor adult, pediatric & neonate patient.
  •  Low perfusion working possible.
  •  Various display screen : Trend Coexist Display, OxyCRG Dynamic View Display, Bed to Bed view Display.
  •  Arrhythmia Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S-T segment analysis, pacemaker detection Drug calculation and titration table.
  •  Networking capacity and nurse call system.
  •  Large volume of tabular and graphic trends information storage and easy to recall.
  •  Capture dynamic waveforms.
  •  In-built Rechargeable battery which provides a backup time of upto 4 hours.
  •  User friendly menu structure with easy to use rotary dial.
  •  Protection Against electrosurgical interference and defibrillation.
  •  Intelligent audio and visual comprehensive alarm. Volume adjustment possible.

TECHNICAL SPECIFICATION

Lead Mode5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selectionI, II, III, avR, avL, avF, V,
Waveform2 ch
Lead mode.3 Leads ( R, L, F or RA, LA, LL) Lead selection : I, II, III, Waveform : 1 ch
Gain2.5mm/mV, 5.0mm/mV, lOmm/mV, 20mm/mV, auto
Adult15 ~ 300 bpm
Neo/Ped>15 ~ 350 bpm
Accuracy± 1% or ± 1 bpm,which great
Resolution1 bpm
Surgery1 ~ 15 Hz
Monitor0.5 ~ 35 Hz
Diagnostic0.05 ~ 100 Hz
ST Segment Monitoring RangeMeasure and Alarm -2.0 ~ +2.0 mV
TypeASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
RESPIRATIONSp02
Method : R-F(RA-LL) ImpedanceMeasuring Range : 0 ~ 100 % Alarm Range : 0 ~ 100 %
Resp. Rate Measuring and Alarm RangeResolution : 1 %
Adult : 0 ~ 1 20 rpmAccuracy : 70% ~ 100% ±2 %
Neo/Ped : 0 ~ 150 rpm0% ~ 69% unspecified
Resolution : 1 rpm
Accuracy : ±2 rpm
Apnea Alarm : 10 ~ 40s
NIBPTemperature
Method: OscillometricChannel: 2
Mode: Manual, Auto, STATMeasuring and Alarm Range: 0 ~ 50°C
Pulse Rate Range: 40 ~ 240 bpmResolution: 0.1 °C
Alarm Type : SYS, DIA, MEANAccuracy: ±0.1 °C
Measuring and alarm rangeIBP
Adult ModeLabel: ART, PA, CVP, RAP, LAP, ICP, PI, P2
SYS: 40 ~ 270 mmHgMeasuring and alarm range
DIA: 10 ~ 215 mmHgART: 0 ~ 300 mmHg
MEAN: 20 ~ 235 mmHgPA: -6 ~ 1 20 mmHg
Pediatric ModeCVP/RAP/LAP/ICP: -10 ~ 40 mmHg
SYS: 40 ~ 200 mmHgP1/P2: -10 ~ 300 mmHg
DIA: 10 ~ 150 mmHgPress Sensor Sensitivity: 5uV/V/mmHg Impedance : 300-3000Q
MEAN: 20 ~ 165 mmHgResolution: 1 mmHg
Neonatal ModeAccuracy: ±2% or ± 1 mmHg, which is greater
SYS: 40 ~ 135 mmHgActualization interval : about Is
DIA: 10 ~ 100 mmHgDimension: 320 x 160 x 270mm
MEAN: 20 ~ 1 10 mmHgDimension: 320 x 160 x 270mm
Resolution Pressure: lmmHgNet Weight : <5kg
Accuracy Pressure Maximum Mean error : ±5 mmHgGross Weight : <8kg
Overpressure Protection
Adult Mode: 297±3 mmHg
Pediatric Mode: 240±3 mHg
Neonatal Mode: 147±3 mmHg